As I said in my last post, sometimes I' am contacted by companies to help them pass EMC. I like the challenge and I know that I will learn something new.
In this post, I'll share some things that I do at the beginning of an investigation.
When you have a product that doesn't pass EMC, most of the time the radiated emission will give you enough tips to guide you on where to start the investigation. It is like a photo on a crime scene, you have some tips and your job is to put all of them together to resolve the puzzle.
Another reason why you should start fixing the radiated emission first is that once you have fixed it most of the time the radiated immunity is also improved.
What I do I divide the emission into 2 or 3 ranges.
Frequency below 100 - 200 MHz, the emission is usually coming from the cables... while frequency above let says 300 MHz up (usually there is something wrong at PCB level).
Tor frequency below 100-200 MHz the usual suspects are DCDC converter, AC/DC converter, dimming circuits, etc.
Then by looking at the emission shape you can create a list of suspects...
For example, look at the photo attached to this post. you will notice that in the range 35MHz - 70 MHz there is a typical shape of the emission of a DCDC converter.... (they always look like a bell spread over a range in this case of 30 - 40 MHz ). Sometimes the emission can be even at a lower frequency range... the point is that it looks like a bell.
Then you need to prove it!, and there are several ways... depending on the kind of DCDC converter the cure could be different...
(maybe next time I may discuss this)
What I want to say here is that EMC is not "black magic" and if you have enough experience you can identify the most likely cause of emission by just looking at the radiated emission graph and the frequency.
Therefore you should not be intimidated by visiting an EMC lab instead you should go and learn something new. You will start to see your design, in the frequency domain rather than in the time domain and your skill will grow exponentially!

Written by Francesco Poderico
About the author
These articles are Francesco Poderico's work. He built EMC Design Solutions around a simple idea: EMC is not black magic, and every failure has an explanation. When he closed the company, he passed his writing to us so it could keep helping engineers. We publish it unchanged.
Facing a problem like this one?
We help hardware teams find the root cause and pass. Start with a call, or map the rules that apply to your product first.
More on EMC

EMC
Why Moving the EUT Changes the Emissions Plot
Rotate the product, lift a cable, move it 20 cm, and the radiated emissions plot changes. That is not randomness: the cable is the antenna. How to read those changes while debugging.
Francesco Poderico · · 3 min read

EMC
Power Supply Emissions: How I Separate Differential Mode from Common Mode
One bench test tells you whether DC/DC converter emissions are differential or common mode: change the load and watch the amplitude. What each result means and where to fix.
Francesco Poderico · · 3 min read

EMC
Identifying Low di/dt and High di/dt Currents in DC‑DC Converters
Not all currents in a switching converter matter equally for EMI. How to identify the high di/dt loops, why they dominate emissions, and the layout and gate-driver choices that tame them.
Francesco Poderico · · 4 min read